Page 10-1017PDMODULE, TDMODULE (Data Module)
10
3 ABORT No response from EPF audit.
4 ABORT Internal System Error.
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at one-minute intervals a
maximum of five times.
3. If the test continues to abort, escalate the problem.
5 ABORT Ringer update aborted (data module not in the
in-service state).
1. Verify that the data module is powered (power LED
on).
2. Make sure data module is connected to the building
wiring, check for faulty wiring, check for faulty data
module.
3. Retry the command at one-minute intervals a
maximum of five times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line
circuit pack and repeat the test.
6. If the test continues to abort, escalate the problem.
6 ABORT Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at one-minute intervals a
maximum of five times.
3. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not
available.
2000 ABORT Response to the test request was not received within the
allowable time period.
Table 10-291. TEST #17 Data Module Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation