Page 10-1290STBY-SPE (Standby SPE)
10
2025
(cont’d.)
ABORT If the red LED on the Standby SPE Memory circuit pack is on, replace
the Standby SPE Memory circuit pack as described in Chapter 6,
‘‘Reliability Systems: A Maintenance Aid’’ and proceed with Steps 10,
11, and 12.
If the red LED on the carrier A Duplication Interface circuit pack is on,
replace the carrier A Duplication Interface circuit pack as described in
Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and proceed with
Steps 11, 12, and 13.
If none of the three red LEDs is on AND if this is the first attempt to clear
the problem, replace the Standby SPE Processor circuit pack as
described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’ and
proceed with Steps 10, 11, and 12.
If none of the three red LEDs is on AND if this is the second attempt to
clear the problem (that is, the Standby SPE Processor circuit pack has
already been replaced), replace the Standby SPE Memory circuit pack
as described in Chapter 6, ‘‘
Reliability Systems: A Maintenance Aid’’
and proceed with Steps 10, 11, and 12.
If none of the three red LEDs is on AND if this is the third attempt to
clear the problem (that is, the Standby SPE Processor and Standby
SPE Memory circuit packs have already been replaced), replace the
carrier A Duplication Interface circuit pack as described in Chapter 6,
‘‘Reliability Systems: A Maintenance Aid’’ and proceed with Steps 10,
11, and 12.
Table 10-392. Test Result Error Codes Associated with the Standby SPE
Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page