Page 10-1459TIE-TRK (Tie Trunk)
10
Table 10-443. TEST #33 Loop Around and
Conference Circuit Test
Error
Code
Test
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to
run this test. This could be due to a failure to seize the
port.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
7 ABORT The conference circuit test was aborted.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
129 ABORT The 404-Hz reflective loop around test aborted.
Response to the test request was not received within the
allowable time period.
131 The 1004-Hz reflective loop around test aborted.
Response to the test request was not received within the
allowable time period.
133 The 2804-Hz reflective loop around test aborted.
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1 minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.