Maintenance Object Repair Procedures
Page 10-1462TIE-TRK (Tie Trunk)
10
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to
run this test. This could be due to a failure to seize the
port.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2. If the test continues to abort, escalate the problem.
7, FAIL The conference capabilities of the port failed (Error
Code 7).
129, The reflective 404-Hz Tone Test failed. No transmission
was detected to or from the port (Error Code 129).
131, or The reflective 1004-Hz Tone Test failed. No transmission
was detected to or from the port (Error Code 131).
133 The reflective 2804-Hz Tone Test failed. No transmission
was detected to or from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or
tone problems are suspected (see notes on the next
page).
1. To make sure the problem is on-board, disconnect
the port from the CO and retry the test. Coordinate
this with the CO, or do it after busy hours; otherwise,
the CO may put the connection out of service.
2. If the retry fails, replace the circuit pack.
3. If the retry passes and no troubles have been
reported, disable the test. If the retry passes and
troubles have been reported, refer the problem to
the CO.
More information continues on the next page.
Table 10-443. TEST #33 Loop Around and
Conference Circuit Test Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page