Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1472TIE-TRK (Tie Trunk)
10
1004 ABORT The port was seized by a valid call during the test. The
test has been aborted. Use the display trunk xx to
determine the trunk group/member number of the port.
Use the status trunk command to determine the service
state of the port. If the service state indicates that the
port is in use, the port is unavailable for certain tests.
(Refer to the "Status Commands" section in Chapter 8,
‘‘Maintenance Commands and Trouble-Clearing Aids’’
for a full description of all possible states.) You must wait
until the port is idle before retesting.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, and the port is not in
use, escalate the problem.
1005 ABORT This test is not valid for this trunk translation. Must be a
Type-1 standard trunk for this test to run.
1. Check trunk configuration. If it is not a Type-1
standard trunk, this abort message should be
ignored.
1014 ABORT The test was aborted because the circuit pack has not
been inserted into the system.
1. Use the list configuration board command to make
sure the circuit pack is inserted in the carrier.
2. If the board is not inserted, make sure the circuit
pack is inserted in the carrier and fully seated.
3. If the test continues to fail, escalate problem.
1040 ABORT This test is not performed for trunk ports administered as
"access endpoints."
1. Verify this port is an access endpoint by using the
display port command.
2. If the port has been administered as an access
endpoint, this test should abort.
Table 10-446. TEST #74 Tie Trunk EPF Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page