Maintenance Object Repair Procedures
Page 10-1585UDS1-BD (UDS1 Interface Circuit Pack)
10
2100 ABORT Could not allocate the necessary system resources to
run this test.
1. Retry the command at 1-minute intervals for a
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
FAIL If the UDS1 connects to a T1 network facility or to
another switch, do the following:
1. The performance of the DS1 link between the UDS1
interface circuit pack and the remote DS1 endpoint
is poor. Enter the list measurement ds1-log PCSS
command to read the error seconds measurement.
2. Verify that both endpoints of the DS1 link are
administered using the same signaling mode,
framing mode, and line coding.
3. Contact T1 Network Service or the technician at the
remote switch to diagnose the equipment.
4. Check the physical connectivity of the UDS1
interface circuit packs and the cable.
5. Replace the local UDS1 interface circuit pack, and
repeat the test.
6. If the test still fails, escalate the problem.
Information continues on the next page.
Table 10-465. TEST #143 Minor Alarm Inquiry Test Continued
Error
Code
Test
Result Description/ Recommendation