Maintenance Object Repair Procedures
Page 10-1677XXX-BD (Common Port Circuit Pack)
10
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
PASS Ringing current is detected or this vintage of the Analog
Line circuit pack does not support the Ringing
Application Circuit Test. Analog Line circuit packs that
DO NOT support Test #51 include TN712 Vintage 13
and earlier and TN742 Vintage 3 and earlier.
any NO
BOARD
This is normal if the test is being done when (a) the
circuit pack is not physically in the system or (b) the
system is booting up. Otherwise, there is some
inconsistency between the physical configuration and
the data kept in the system.
1. Verify that the circuit pack is physically in the
system. Verify that the system is not in a stage of
booting up. Retry the command at one-minute
intervals for a maximum of five times. If the test
continues to return NO BOARD, escalate the
problem.
Table 10-494. TEST #52 Control Channel Loop Around Test
Error
Code
Test
Result Description/ Recommendation
none or
2100
ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a
maximum of five times.
2. If the test continues to abort, escalate the problem.