user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-467status journal-link
8
subjective data because the ISDN trunk may be used for data or voice. If the
trunk is used for data and the rates are high, the trunk should be taken out of
service. If the trunk is used for voice, the trunk may not have to be taken out of
service. Also, high rates may be due to some type of power hit on the line.
status journal-link
This command displays the status of a wakeup-log or a pms-log printer link.
Synopsis
status journal-link [ wakeup-log | pms-log ]
print
Permissions
The following default logins may execute this command: system technician,
inads, cust, rcust, bcms, init, browse.
Examples
status journal-link wakeup-log
status journal-link pms-log
status journal-link pms-log print
Description
Either command displays whether the link is up or down. If the link is down, the
number of times the switch has tried to set up the link is shown. A journal printer
documents the automatic wake-up events, emergency access to attendant
events, and housekeeping events when the property management system is not
functional. A journal printer may also generate reports of the automatic wake-up
events and the emergency access events at a scheduled time. If system
configuration includes two printers, one is for the housekeeping events only and
the second is for automatic wake-up events and emergency access events only.
For general information on journal printer links, see the second paragraph in the
"Description" section of the "busyout journal-printer" pages.
Defaults
No defaults.