user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-499status signaling-group
8
Defaults
None.
Parameters
Help Messages
If the system technician presses HELP after entering "status signaling-group", the
following is displayed:
Enter group identifier (1-8) [’print’]
Error Messages
If the specified group identifier is non numeric or out of range, the following
message is displayed:
Signaling group invalid
If the specified group identifier is not administered, the following message is
displayed:
No signaling group assigned
If the software data cannot be sent to the SAT, the following message is
displayed:
Error encountered, can’t complete request
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message is displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message is displayed:
All maintenance resources busy; try again later
group identifier The signaling group identifier is an administered number associated
with each signaling group (1-8).
print This will cause the report to be printed if a printer is linked to the SAT.