user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-509status system
8
Output
For the following output example, the command that was entered is "status
synchronization".
Feature Interactions
None.
status system
This command displays the status, mode, and operational attributes of the
SPE(s), TDM and Packet busses, tone-clock circuit pack(s), expansion interface
links (exp-links), and emergency transfer switch of a single cabinets or all
cabinets in the system.
Stratum Level This is the synchronization stratum level, either a "3"
or "4."
Maintenance Name: Either "TONE-BD," "DS1-BD," or "STRAT-3."
Physical Location The board location of the selected DS1 or tone-clock
circuit pack. This includes the cabinet-carrier-slot for
a DS1 or the cabinet-carrier for a tone-clock.
Switching Capability Whether the on-line reference for synchronization can
be switched. "Enabled" and "Disabled" are used to
describe the current capacity for reference switching.
Excessive Reference Switching This field gives a high level description of how many
times the synchronization reference has been
switched. If excessive reference switching is taking
place (sync error 1793 is at threshold) this field
displays "Yes," otherwise "No" is displayed.
status synchronization
SYNCHRONIZATION STATUS
Stratum Level:4
Maintenance Name: TONE-BD Physical Location: 01A
Switching Capability: Enabled
Excessive Reference Switching: No