user manual

DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-535test alarms
8
For the following output example, the command "test access-endpoint 22502"
was entered. Assume that the access endpoint ports for extension 22502 are in
cabinet 1, carrier C, slot 11, circuit 1 to 6.
Feature Interactions
None.
test alarms
This command tests the hardware associated with selected alarms
Synopsis
test alarms
auto-page failures step [ short | long ][ repeat number | clear ]
Permissions
The following default logins may execute this command: system technician,
inads, init, nms.
Examples
test alarms
test alarms step failures
test alarms long clear auto-page
test alarms long failures
test access-endpoint 22502 short page 1 of 1
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1101 WAE-PORT 22502 36 PASS
01C1102 WAE-PORT 22502 36 PASS
01C1103 WAE-PORT 22502 36 PASS
01C1104 WAE-PORT 22502 36 PASS
01C1105 WAE-PORT 22502 36 PASS
01C1106 WAE-PORT 22502 36 PASS
Command Successfully Completed