User's Manual
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r 
555-233-115 
Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory 
3-54Release 5/6si to Release 8r 
3
Enable Customer Options and Alarm Origination 
to INADS
1. Get the DOSS order number of the upgrade from the project manager and 
ask the regional Customer Software Administration to complete the steps 
in the shaded box. See ââWhere to Call for Technical Supportââ on page -xx
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database 
Administrator enables Alarm Origination.
2. When administration is completed, log in as 
craft
 at the 
Login:
 prompt.
"init" login administration:
1. Log in as 
init
.
2. Type 
change system-parameters customer-options
 and press 
Enter 
to verify that the customer options are properly set.
3. Go to screen 6, QSIG Optional Features, and set the 
Basic Call 
Setup 
field to 
y
 if the customer was using Supplementary Services 
Protocol b or d on an ISDN-PRI trunk group before the upgrade.
4. Type 
change system-parameters offer-options
 and press 
Enter.
5. If the 
Activate Offer
 field is 
n
, set it to
 y 
and press 
Ta b . A warning 
message lets you know whether you need to save translations and 
reboot to make the change permanent.
6. Press 
Enter to effect the changes or Cancel if there were no changes.
7. Contact the requester when done.