User's Manual
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r 
555-233-115 
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-29Standard Reliability 
5
For Two Collocated Expansion Port Networks
1. Behind control carrier A of PPN cabinet 1:
■ Install a lightwave transceiver on cable connector at slot 1A02.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transceiver
■ Connect 1 end of the fiber optic cable to the lightwave transceiver, 
just installed, at slot 1A02.
■ Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.
2. Behind control carrier A of EPN cabinet 3:
■ Install a lightwave transceiver on cable connector at slot 3A01.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transceiver
■ Connect the other end of the fiber optic cable to the lightwave 
transceiver, just installed, at slot 3A01.
■ Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.
■ At the top of the cabinet, coil up the surplus fiber optic cable and 
attach it to the wall of the cable tray.
3. Behind control carrier A of EPN cabinet 2:
■ Install a lightwave transceiver on cable connector at slot 2A02.
NOTE:
Attenuators may be required for single mode fiber using a 
300A Lightwave Transceiver
■ Connect 1 end of the fiber optic cable to the lightwave transceiver, 
just installed, at slot 2A02.
■ Carefully attach the fiber optic cable (with cable ties) to the wall of 
the cable tray at the built-in cable tie positions.