Adding or Removing Cabinet Hardware 
6-64Add IP Interface Assembly 
6
Administration Steps
1. Log in as 
craft
.
2. Type 
change circuit-pack
 and press 
Enter.
3. Check the Code column to see if the slots above the TN802B say 
DSMAPD or MEDPRO.
.
4. If MEDPRO, go to the entry just above the TN802B that says MEDPRO.
5. Type DSMAPD, and press 
Enter. Changing the one entry automatically 
changes the entry above it. If it is in IP Trunk mode, you get the following 
error message:
MedPro type requires TN802 with application. Type 
MEDPRO on circuit-packs form.
Log onto the TN802B Interface Server 
If administered remotely through pcANYWHERE:
1. Dial in to the server through pcANYWHERE using the dialup number 
supplied. 
2. Click on the pcANYWHERE Remote Host Computer button on the toolbar 
to send 
CTRL ALT DEL to the host.
3. Type 
administrator
 in the 
User Name
 field.
4. Type 
iptrunk
 in the 
Password
 field and click 
OK
. 
5. After logging on for the first time, change the administrator password and, 
if desired, the user name, to ensure security. See your Windows NT server 
documentation for details.
change circuit-packs     Page 1 of 5 
       CIRCUIT PACKS         
 Cabinet: 1 Carrier: A
 Carrier Type: processor 
 Slot Code Sf Mode Name Slot Code Sf Mode Name
11: DSMAPD RESERVED-IP
01: TN754  DIGITAL LINE  12: DSMAPD  RESERVED-IP
02: TN758  POOLED MODEM  13: TN802 B  MAPD BOARD
03: TN2144  ANALOG LINE  14: 
04: TN746 B  ANALOG LINE  15: 
05 16: 
06: TN771 C  MAINTENANCE/TEST 
07: TN464 F  DS1 INTERFACE 
08: TN2140  E&M TIE TRUNK 
09: TN767 E  DS1 INTERFACE 
10: TN799 B  CONTROL-LAN 
 ’#’ indicates circuit pack conflict.