User's Manual
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r 
555-233-115 
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-71Add IP Interface Assembly 
6
If administered remotely through pcANYWHERE:
21. Click on the pcANYWHERE Restart Host Computer button on the toolbar 
to restart the computer.
If administered locally on a monitor, keyboard, and mouse:
21. Click 
Yes
 in the dialog box to restart the computer. 
!
WARNING:
When connected remotely via pcANYWHERE, only use the pcANYWHERE 
Restart Host Computer button on the toolbar to restart Windows NT.
Check Network Services
When the server restarts, make sure that the required network services have 
started correctly. If you see an error dialog box, then the network services did not 
start correctly. Also, check the NT Event Log.
1. Click on 
My Computer > Control Panel > Network > Services. 
Make 
sure that the following services are listed:
■ Computer Browser
■ Microsoft Internet Information Server 2.0
■ NetBIOS Interface
■ RPC Configuration
■ Server
■ Workstation
2. Click the 
Protocols 
tab, and examine the Network Protocols. TCP/IP 
protocol should be the only one listed.
3. Click 
OK
.
Test the External Connection to the LAN
To test the external IP connections, ping the IP Interface server and ping a known 
computer connected to your network.
1. Click 
Start > Programs > Command Prompt
.
2. Type 
ping 
nnn.nnn.nnn.nnn
 (which is your IP address).
■ If everything is configured correctly, the system responds with the 
following message:
Reply from nnn.nnn.nnn.nnn: bytes=32 time<##ms 
TTL=###
■ If no response, verify the IP-address information and check the 
connectivity, including the cabling.