Adding or Removing Cabinet Hardware 
6-78Add IP Interface Assembly 
6
Circuit Pack Verification
1. Type 
change circuit-pack
 and press Enter.
2. Check the Code column to see if it says DSMAPD or MedPro.
.
3. To correct it, go to the entry just above the TN802B that says DSMAPD.
4. Type MEDPRO, and press 
Enter. Changing the one entry automatically 
changes the entry above it. If it is in IP Trunk mode, you get the following 
error message:
MedPro type requires TN802 with application. Type 
MEDPRO on circuit-packs form.
5. To complete the administration, refer to the 
DEFINITY ECS Release 8 
Network Connectivity
 book.
change circuit-packs     Page 1 of 5 
       CIRCUIT PACKS         
 Cabinet: 1 Carrier: A
 Carrier Type: processor 
 Slot Code Sf Mode Name Slot Code Sf Mode Name
11: MEDPRO RESERVED-IP
01: TN754  DIGITAL LINE  12: MEDPRO  RESERVED-IP
02: TN758  POOLED MODEM  13: TN802 B  MAPD BOARD
03: TN2144  ANALOG LINE  14: 
04: TN746 B  ANALOG LINE  15: 
05 16: 
06: TN771 C  MAINTENANCE/TEST 
07: TN464 F  DS1 INTERFACE 
08: TN2140  E&M TIE TRUNK 
09: TN767 E  DS1 INTERFACE 
10: TN799 B  CONTROL-LAN 
 ’#’ indicates circuit pack conflict.