Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-10Upgrade the software and hardware 
1
Check TTI Status 
1. Type 
status TTI
 and press Enter. Wait until the 
Percent Complete
 field 
shows 
100%
.
Busyout MMI Circuit Packs (H/C only)
!
CAUTION:
Multimedia-to-voice station calls are not preserved on an upgrade. Failure to busy-out 
the TN787 Multimedia Interface (MMI) circuit packs results in unusable TN787 and 
TN788 Multimedia Voice Conditioner ports.
1. Type 
display system-parameters customer-options
 and press Enter. On 
screen 2 under the Multimedia Call Handling (MMCH) options, check the 
Basic
 and 
Enhanced
 fields. 
2. If either the 
Basic
 or 
Enhanced
 field is 
y
, type 
list configuration all
 and 
press 
Enter to locate all MMI (TN787) circuit packs.
3. If there are MMI circuit packs, type 
busyout board 
cabinet carrier slot
and press 
Enter to remove the circuit packs from service.
Lock the active SPE (H/C only)
1. Type 
status spe
 and press Enter to determine which control carrier is 
active or observe the control carrier LEDs.
NOTE:
For high or critical reliability systems, we recommend that you 
replace the circuit packs in the standby carrier first.
!
CAUTION:
When replacing any hardware, be sure to ground yourself against 
electrostatic discharge (ESD) by wearing a grounded wrist strap.
2. Move the SPE-SELECT switches on both Duplication Interface (DUPINT) 
circuit packs, 
one at a time
, to the active carrier. 