User's Manual
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r 
555-233-115 
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-16Upgrade the software and hardware 
1
Verify software version
NOTE:
The 
Tape Resident
 field shows the software load number. Write it down 
for use later.
If standard reliability:
1. Type 
list configuration software-version 
and press 
Enter to verify that the 
removable media contains the Release 8 software. This takes about 2 
minutes.
If high or critical reliability:
1. Type 
list configuration software-version long
 and press 
Enter to verify 
that the removable media contains the Release 8 software.
Save Translations
1. Type 
save translations tape 
and press Enter to save translations to the 
new removable media, which takes about 2 minutes.
Save Announcements (if necessary)
1. Type 
save announce
tape
 and press Enter to save announcements to the 
new removable media.
Restore Disk
If standard reliability:
1. Type 
restore disk full
 and press 
Enter to write the new software to disk. 
Release 8 system software is now resident on the disk.
If high or critical reliability:
2. Type 
restore disk full both
 and press 
Enter to write the new software to 
disk. 
NOTE:
This command may take up to 25 minutes to complete. Until this 
command finishes, the system provides no user feedback on the 
system access screen. Do not press 
Enter while the command 
executes. Doing so clears the terminal screen as the command 
finishes, erasing any success or failure messages the system may 
provide.