Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-17Upgrade the software and hardware 
1
Upgrade Software 
This command copies the software from the removable media to the system disk 
and takes about 15 minutes to complete. 
For standard reliability:
!
CAUTION:
All calls are dropped—this is a service interruption.
1. Type 
upgrade software G3V8r.xx.x.xxx.x 
(entire alphanumeric string of 
new software version) and press 
Enter. At the prompt, press Enter to save 
translations.
For high or critical reliability:
1. Type 
upgrade software G3V8r.xx.x.xxx.x no-calls 
(entire alphanumeric 
string of new software version) and press 
Enter. At the prompt, press Enter 
to save translations and attempt to preserve calls across the interchange.
For all reliabilities:
2. After the system resets, log in as 
craft
. 
3. Check for the 
Translation Corruption Detected
 message before 
proceeding with the upgrade. If corruption is detected, refer to No 
Translations After Upgrade in 
Appendix B, ‘‘Troubleshooting an Upgrade’’
to correct the problem. 
!
CAUTION:
Do not continue with the upgrade until the translations errors are 
corrected. 
Reset SPE status (H/C only)
1. Type 
status SPE
 and press Enter. Wait until the 
Standby Handshake
field displays 
up, which takes about 3 minutes.
2. Type 
reset spe-standby 4
 and press 
Enter.
NOTE:
You can continue the process while the SPE is resetting.
List Configuration Control 
1. Type 
list configuration control
 and press Enter to verify the system 
recognizes the third TN1650B Memory circuit pack. 