Installing a DEFINITY ECS ATM-PNC
3-8Synchronization Installation and Testing
3
Figure 3-3. 402A synchronization splitter
Figure Notes:
1. Amphenol connector to
DEFINITY ECS
2. Network timing connection
3. Timing alarm lead connection
4. Timing output ports (RJ45) to ATM switch
1
5. Jumpers and capacitors (inside case). See
Figure 3-5 for settings.
1. Ports J1 and J2 provide identical DS1 timing source signals to the ATM switches.
The ATM switch can use two separate DS1 timing signals (one at a time from two
separate spans).