User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-529DIOD-DS1 (DS1 DIOD Trunk) 
3
Conference Circuit Test (#7)
One or more Network Processing Elements (NPEs) reside on each circuit pack 
with a TDM Bus interface. (The TN464 UDS1 circuit pack has one SCOTCH-NPE 
chip instead of several NPE chips). The NPE controls port connectivity and gain, 
and provides conferencing functions on a per-port basis. The Conference Circuit 
Test verifies that the NPE channel for the port being tested can correctly perform 
the conferencing function. The NPE is instructed to listen to several different 
tones and conference the tones together. The resulting signal is then measured 
by a tone detector port. If the level of the tone is within a certain range, the test 
passes.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281—Loss of signal
1793—Blue Alarm
2049—Red Alarm
2305—Yellow Alarm
1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the 
procedures given in the appropriate DS1-BD or UDS1-BD maintenance 
documentation for the listed error types.
FAIL The NPE of the tested port was found to be transmitting in error. This will 
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles 
on this port should be investigated using other port tests and examining 
station, trunk, or external wiring.
Table 3-222. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page