User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-530DIOD-DS1 (DS1 DIOD Trunk) 
3
Table 3-223. TEST #7 Conference Circuit Test 
Error 
Code
Te st 
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may 
be in use on a valid call. Use the status station or status trunk command 
to determine when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use the status station 
or status trunk command to determine when the port is available for 
testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT Test disabled via administration. This only applies to analog stations.
1. To enable test, set the Test field on the station administration screen 
for the particular analog station being tested to ‘‘y.’’ Use the change 
station extension command.
1020 ABORT The test did not run due to a previously existing error on the specific port 
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack:
1281—Loss of signal
1793—Blue Alarm
2049—Red Alarm
2305—Yellow Alarm
1537—Hyperactivity
Look for the above error types in the Hardware Error Log and follow the 
procedures given in the appropriate DS1-BD or UDS1-BD maintenance 
documentation for the listed error types.
FAIL The NPE of the tested port did not conference the tones correctly. This will 
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated by using other port tests and 
by examining station, trunk, or external wiring.
Continued on next page