Maintenance Objects 
3-628E-DIG-BD (Multi Application Platform Board) 
3
E-DIG-BD (Multi Application 
Platform Board)
The maintenance strategy for DIG800-BD is the same as the one described for 
MO-COMBD (MO-XXX-BD). Maintenance testing of the common circuit pack is 
handled by on-board firmware and SPE-controlled tests. Maintenance software 
queries the firmware for error and alarm information, status, and test results. The 
firmware automatically reports error conditions that will result in SPE-controlled 
testing.
Board Insertion
The switch makes an additional board query if any of the following circuit packs 
are inserted:
For any of the above initial board up-links, the switch sends queries requesting 
additional data from the board for administration purposes, while also telling the 
board the switch software release and the system type.
For the native mode, the response to the board query downlink messages 
consists of several CCMS uplink messages that identify the true board code, 
vintage, suffix, emulation type, and the number of reserved slots it needs.
Hyperactivity
The common circuit pack is considered "hyperactive" if the service dispatcher 
receives 200 up-link messages from the circuit pack in a 10-second period. 
Since MAPD has 32 ports, the hyperactivity limit is increased to 500 up-link 
messages per 10seconds. An alarm is issued and the board taken out of service 
when the limit reaches 400 or when it hits 500 up-link messages in 10 seconds.
MO Name (in 
Alarm Log)
Alarm 
Level Initial Command to Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for example, 
A, B, or C); and SS is the address of the slot in the carrier where the circuit pack is located 
(for example, 01, 02, ...).
Full Name of MO
DIG800-BD MIN test board PCSS sh MO800DIG-BD
DIG800-BD WRN test board PCSS sh MO800DIG-BD
Circuit Pack Vintage
TN754 49