Maintenance Objects 
3-642EMG-XFER 
3
Table 3-264. TEST #124 Emergency Transfer Query Test 
Error 
Code
Te st 
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to ABORT with error code 2000, check for system 
powering problems with the A carrier. Resolve all CABINET alarms. 
Then, repeat the test.
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 FAIL Emergency Transfer is manually turned OFF via the Emergency Transfer 
switch.
2 FAIL Emergency Transfer is manually turned ON via the Emergency Transfer 
switch.
1. Place the switch in the AUTO position.
PASS The system software has control of Emergency Transfer. If Emergency 
Transfer is invoked, then there can be a Major alarm in the system that is 
invoking Emergency Transfer. Table 3-265
 lists the error types and MOs 
that may cause Emergency Transfer. If any or all of these errors appear in 
the log, then refer to the appropriate Maintenance documentation and 
resolve those problems first.
If none of these errors appear in the log, then check the Emergency 
Transfer hardware. 
Continued on next page
Table 3-265. Test #124 Error Log Entries That Cause Emergency 
Trans fer 
MO Name Error Type Aux Data
SW-CTL 1
SW-CTL 2
TONE-BD 1 0
TONE-BD 2305 0
Continued on next page