User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-774MAPD-BD (MAPD Interface Circuit Pack TN802) 
3
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4 
and 6 in Figure 3-32
) have not worked loose.
b. Otherwise, replace the circuit pack.
3. At the command prompt, type 
ping 10.32.64.97
 (the internal IP trunk 
server address) and press 
Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4 
and 6 in Figure 3-32
) have not worked loose.
b. Otherwise, replace the circuit pack.
4. At the command prompt, type 
ping 10.32.64.96
 (the IP address of the 
internal Motorola MPC860 processor) and press 
Enter.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4 
and 6 in Figure 3-32
) have not worked loose.
b. Otherwise, replace the circuit pack.
5. Ping the gateway: at the command prompt, type 
ping XX.XXX.XXX.XXX
(the IP address of the gateway) and press 
Enter.
6. When finished, at the command prompt type 
exit
 and press 
Enter.