User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-778MAPD-BD (MAPD Interface Circuit Pack TN802) 
3
Error Log Entries and Test to Clear Values
Table 3-325. Replacing the TN802 hard drive
Step Description Comments
1. Shut down NT Shut down Windows NT by either method 
described in the ‘‘Shutting down NT on the 
TN802’’ section.
2. Remove the circuit pack Unlatch the circuit pack and remove it from 
the carrier.
3. Remove the hard drive Remove the 2 screws and lift the hard drive 
out of its mounting bracket.
4. Replace the hard drive Position the new hard drive in the mounting 
bracket and replace the 2 screws (Step 3).
5. Replace the circuit pack Slide the circuit pack into the slot and lock 
the latching lever.
6. Wait for initialization Wait for
■ the circuit pack to reseat (faceplate 
LEDs light then go out
■ Windows NT boots (PC BOOT displays 
on the faceplate LCD)
■ IP Trunk application to run (IP TRK # 
displays on the faceplate LCD)
Continued on next page
Table 3-326. MAPD (TN802) Error Log entries
Error 
Type
Aux
Data Associated Test
Alarm
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test board UUCSS
1 (a) 0 Circuit pack removed or 
SAKI Test (#53)
MIN/ 
WRN
2
ON
2 (b)
18 (c) 0 busyout board UUCSS WRN OFF release board UUCSS
23 (d) 0 WRN OFF add ds1 UUCSS
125 (e) none 3 None MIN/ 
WRN
3
ON
Continued on next page