 Maintenance Objects
3-799MEDPRO (Media Processor MAPD Circuit Pack) 
3
FAIL The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pack is one of the Port circuit 
packs, replace the circuit pack. Otherwise, if the circuit pack is part of 
the SPE, use the procedure described in 
Replacing SPE Circuit Packs
 in 
Chapter 5.
3. Retry the command a maximum of 5 times.
PASS Communication with this circuit pack is successful.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could be 
due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the MedPro 
interface if it is not already administered.
2. If the board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If this is the case, the 
board is shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the 
busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the port.
Table 3-343. TEST #52 Control Channel Looparound Test — Continued