 Maintenance Objects
3-945PR-MAINT (Maintenance Processor) 
3
MTP Outpulse Relay Test (#102)
This test is a nondestructive test. The test validates the correct operation of the 
remote access CO trunk used by INADS. The MTP first goes off-hook, then 
on-hook on this trunk. If the loop current is detected, the test passes. This test is 
not allowed if the remote access line is in use.
PASS The Maintenance/Tape Processor was reset, and it passed initialization 
correctly. The other MTP tests should be examined to verify that the MTP is 
functioning correctly.
1. Enter test processor a/b and verify that the MTP is functioning 
correctly.
Table 3-408. TEST #102 MTP Outpulse Relay Test 
Error 
Code
Te s t 
Result Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
1018 ABORT The test has been disabled via administration.
1. To enable the test, issue the change system-parameters maintenance 
command, and set the test remote access port field to "y." (If you have 
an INADS line, set the field to "y." If you are testing the Standby 
PR-MAINT, a refresh spe-standby command must be successfully 
executed before you proceed to Step 2.
2. Rerun the test.
Continued on next page
Table 3-407. TEST #101 MTP Reset Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page