3-976RING-GEN (Analog Ring Generator) 
3
RING-GEN (Analog Ring Generator)
All analog phones must be provided with a ringing voltage. The Analog Ring 
Generator is part of the 650A AC Power Supply. A ringing voltage generator 
failure means that no ringing can occur on analog phones; however, ringing on 
digital and hybrid phones can still occur. The ringing voltage is monitored by the 
Tone-Clock circuit pack. 
Hardware Error Log Entries and Test to Clear 
Valu es
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the following tables when 
inspecting errors in the system. By clearing error codes associated with the 
Analog Ring Generator Initialization Test
, for example, you may also clear errors 
generated from other tests in the testing sequence.
MO Name (in 
Alarm Log)
Alarm 
Level Initial Command to Run
1
1. Where P is an appropriate port network number determined via the Port field from the 
Alarm or Error Log.
Full Name of MO
RING-GEN MAJOR test environment P Analog Ring Generator
Analog Ring Generator Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0 Any Any Any test environment PP
1 Analog Ring Generator Query 
Test (#118)
MAJOR ON test environment PP r 3