 Maintenance Objects
3-1012SYS-LINK (System Links) 
3
Notes:
a. Error Type 13: indicates that the link went down. The link may have gone 
down or never come up. Enter command status sys-link location
 and 
check the value of the field 
Faulted Path
. If the value is 
default
, then 
the link never came up. If the value is 
present
, then the link came up and 
went down.
Follow the Common Procedure described above. Wait for 3 min before 
checking the link state. Repeat the procedure until there are no problems 
with the components. 
b. Error Type 257: indicates that the link has experienced uplink flow control. 
Manifest effect of this error is that the end-point may be hyperactive. The 
system link is alarmed if 4 or more errors of this type are detected within 
10 minutes.
To correct the problem, follow the Common Procedure described above. 
Clear errors and wait for 10 minutes.
c. Error Type 513: indicates that the link has experienced downlink flow 
control. Manifest effect of this error is that some information packets from 
the packet interface board have been lost. The link is reset on first 
occurrence, hence, Error 1025 will also be logged. The system link is 
alarmed if 2 or more errors of this type are detected within 10 minutes.
To correct the problem, follow the Common Procedure described above. 
Clear errors and wait for 10 minutes.
d. Error Type 772: indicates that the link experienced a temporary 
disconnect due to excessive resets or state transitions. The effect of this 
error is that the link is taken down and then brought up again. The system 
link is alarmed if 2 or more errors of this type are detected within 10 
minutes.
To correct the problem, follow the Common Procedure described above. 
Clear errors and wait for 10 minutes.