User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1102TIE-DS1 (DS1 Tie Trunk) 
3
This second part of this test 
CANNOT
 be run on a trunk if one of the following 
cases is true:
1. The trunk direction is administered as an incoming only trunk.
2. The trunk is the 24th port on a DS1 Interface circuit pack which is 
administered using 24th Common Channel Signaling.
3. The trunk has been seized by a normal trunk call.
4. The trunk is administered with maintenance test disabled.
5. The outgoing signal type of the trunk is either automatic or 
immediate-start.
Table 3-489. TEST #136 DS1 Tie Trunk Seizure Test 
Error 
Code
Te s t 
Result Description/ Recommendation
ABORT Internal System Error.
1000 ABORT System resources required to run this test were not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the trunk group/member number of the port. Use the status 
trunk command to determine the service state of the port. If the service 
state indicates that the port is in use, then the port is unavailable for certain 
tests. You must wait until the port is idle before retesting.
1. If the port status is active but the port is not in use (no calls), check the 
error log for error type 1025 (see the error log table for a description of 
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
1004 ABORT Far end is seizing the trunk while the test is ongoing. A glare situation is 
detected. Current test is designed to be aborted. Use the display port 
PCSSpp command to determine the trunk group/member number of the 
port. Use the status trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. You must wait until the port is idle before 
retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
Continued on next page