User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1121TIE-TRK (Tie Trunk) 
3
1040 ABORT (Non-TN497 circuit packs only.) This test is not performed for trunk ports 
administered as access endpoints.
1. Verify this port is an access endpoint by using the display port 
command.
2. If the port has been administered as an access endpoint, this test 
should abort.
2000 ABORT Seizure message is not received back within 10 seconds.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a 
translation match at both ends.
3. Check the facility.
2100 ABORT Could not allocate the necessary system resources to run the test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times. 
3 FAIL (TN439 circuit packs only.) No dial tone detected from the other end.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a 
translation match at both ends.
3. Check the facility.
PASS The relevant seizure test passes. This port is functioning properly.
1. If users are reporting troubles, examine loop connections to the port, 
wiring, and stations.
0NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the 
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage 
between the internal ID and the port.
Table 3-494. Seizure Tests (#73, #747, #73) — Continued
Error 
Code
Te st 
Result Description/ Recommendation
Continued on next page










