User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
 Maintenance Objects
3-1294XXX-BD (Common Port Circuit Pack) 
3
Control Channel Loop Around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies 
its records.
any NO 
BOARD
This is normal if the test is being done when (a) the circuit pack is not 
physically in the system or (b) the system is booting up. Otherwise, there is 
some inconsistency between the physical configuration and the data kept 
in the system.
1. Verify that the circuit pack is physically in the system. Verify that the 
system is not in a stage of booting up. Retry the command at 1-minute 
intervals for a maximum of 5 times.
Table 3-554. TEST #52 Control Channel Loop Around Test 
Error 
Code Test Result Description/ Recommendation
none or 
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The test failed because the circuit pack failed to return the circuit pack 
code or vintage.
1. Retry the command for a maximum of 5 times.
2. If the test still fails, issue the busyout board, reset board, and 
release busy board commands, and then retest.
3. If the problem continues, replace the circuit pack.
4. Run the test again.
PASS Communication with this circuit pack is successful.
any NO BOARD This is normal if the test is being done when (a) the circuit pack is not 
physically in the system or (b) the system is booting up. Otherwise, there 
is some inconsistency between the physical configuration and the data 
kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. ) Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page
Table 3-553. TEST #51 Ringing Application Circuit Test — Continued
Error 
Code
Te s t 
Result Description/ Recommendation
Continued on next page