User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-88display test-schedule 
2
display test-schedule
Automatic Transmission Measurement System (ATMS) provides advanced 
maintenance procedures for monitoring system trunk facilities. This system 
performs transmission tests on system trunks to determine if trunks are 
performing satisfactorily. These tests can be initiated in two ways:
Adjustable 
Make/Break Ratio
This field can be of particular importance when using a modem that 
may be transferable from country to country. The intent of this field 
is to control the make/break ratios of pulses and DTMF dialing. The 
Intel product information has support for the different make/break 
options for pulse dialing only.
Intel uses the option “&P0” to select a ratio of 39% make and 61% 
break for communication within the U.S. and Canada. The option 
“&P1” sets a ration of 33% make and 67% break for the U.K. and 
Hong Kong.
This field is 5 characters long and is case in-sensitive. ( )
Dial Command
This field simply denotes the dialing command of the modem. This 
is a fairly standard command. (D)
No Answer 
Time-Out
Most off-the-shelf external modems provide a timer that abandons 
any outbound data call after a predetermined interval. Some 
modems provide for this timer to be disabled, thus allowing an 
outbound call to ring indefinitely. AT&T Paradyne does not provide 
this capability with their modem line, because it is generally 
undesirable to have an outbound call attempt ring indefinitely. 
The internal modem must have this parameter disabled or set to at 
least 255 seconds.
This is a non-administrable parameter. For the external modem 
connection, this parameter will be the first initialization string to be 
transmitted to the external modem. This field will be visible on the 
administration form in display mode only. 
This hardcoded constant can be overridden for type approval 
applications, specifically in the U.K and other Western European 
nations, by the use of the “Misc. Init. Param:” field. (S7=255)
demand user enters command at the System Administration 
Terminal (SAT) to initiate a test immediately
scheduled schedules tests through a schedule form to automatically 
initiate tests at a predetermined time