User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance for csi systems 
1-4What’s new for R8csi 
1
MEDPROPT
The MEDPROPT maintenance object monitors the health of the MEDPRO digital 
signal processors (DSPs).
The TN802B MAPD (Multi-Application Platform for DEFINITY) Media Processor 
circuit pack provides the audio bearer channels for H.323 voice over IP calls. 
One TN802B circuit pack has one MEDPROPT media processing resource. 
Based on system administration of audio codecs, a MEDPROPT can handle 
either 31 or 22 simultaneous channels of H.323 audio processing. If the 
ip-parameters
 form specifies only G.711 Mulaw or G.711 Alaw as the audio 
codecs, the MEDPROPT can service 31 channels. If any other codec type 
(G.723-5.3K, G.723-6.3K, or G.729) is administered, the MEDPROPT can only 
service 22 channels.
The MEDPROPT is physically made up of 11 individual DSPs, but is treated 
logically as one port. If individual DSPs on the TN802B MAPD fail, the 
MEDPROPT remains in-service at lower capacity.
The MEDPROPT is a shared service circuit. It is shared between H.323 trunk 
channels and H.323 stations. An idle channel is allocated to an H.323 
trunk/station on a call-by-call basis.
AN-LN-PT (and TR-LN-BD)
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID), and the TN797 
Analog Trunk and Line circuit pack both support this Maintenance Object.
The TN793B/TN2793B Analog Line circuit pack (w/ Caller ID) provides 24 ports 
for voice terminals and supports both on-premises and off-premises analog 
voice terminals. 
The TN797 Analog Trunk and Line circuit pack provides 8 ports, each of which 
may be administered in any of several ways, as described in maintenance object 
TR-LN-BD.
NOTE:
The TN793B/TN2793B analog line circuit pack supports analog data 
modules. When assigned, analog data modules provide access to the 
NetPkt (TN794 circuit pack) data ports. To activate an analog data module 
you must assign the port location on the data form and connect a modem 
to the port. The analog data module can be used for connection to a CDR 
output, or other adjuncts as needed. These ports are tested the same as all 
other analog ports on the circuit pack.