Maintenance Commands 
2-163monitor health 
2
CP
Proportion of the CPU currently dedicated to call processing. This 
occupancy has priority over SM and IDLE occupancy categories and 
takes processor time away from these occupancy categories, if 
needed. This percentage is rounded to the nearest integer, therefore 0 
percent means that the occupancy is less than one half of a percent.
Idle
Proportion of the CPU currently available. This percentage is rounded 
to the nearest integer, therefore 0 percent means that the occupancy 
is less than one half of a percent.
Active SPE
Currently-active processor complex. When the active processor 
complex is locked on-line with lock switching on DUPINT, the “lock” 
option displays; otherwise, “auto” displays.
Duplicated?
Duplication status of the SPE (n).
SPE Power
Current power source for the processor complex. The normal state is 
“commercial”. When commercial power is unavailable, in-use battery 
backup is indicated with “backup”.
Time Source
Current timing source is displayed. The display values for this field 
vary according to timing sources selected. If the site administers the 
optional Stratum-3 hardware, “external” displays and “internal” 
displays when an internal source, such as a tone clock, is used. 
Primary and secondary timing sources must be administered when 
using the Stratum-4 option. 
“primary” = primary administered source is in use
“secondary” = secondary administered source is in use. 
“local” = neither the primary or secondary sources are in use.
# Logins
Number of current users.
Cab
Assigned cabinet number, ranging from 1 to the highest cabinet 
number in the system.
Emerg Trans
Current setting of the emergency transfer switch for each cabinet. Five 
options are available: auto-on (“auto+” or “a+”), auto-off (“auto-” or 
“a-*, “on”, “off”, and “n.a.”. If “auto+” or “auto-” option are enabled, 
emergency transfers automatically activate when cabinets fail (“+” 
indicates that emergency transfer is activated, while “-” indicates that 
emergency transfer is inactive). When “on” is displayed, emergency 
transfer automatically activates. The “off” option shows that cabinets 
cannot activate emergency transfers. In duplicated SPE systems, 
switch settings for both processors of the PPN (cabinet 1) display. In 
this case, “auto+” is abbreviated “a+”, “auto-” is d “a-”, and “off” is 
“of”. “on” does not changed. If “n.a.” displays, emergency transfer 
switch settings are not available.
Mj
Number of major alarms associated with the cabinet. An asterisk fills 
the field when the number exceeds 99.
Mn
Number of minor alarms associated with the cabinet. An asterisk fills 
the field when the number exceeds 99.