Maintenance Commands 
2-306status system 
2
SYSTEM CLOCK
Shows which Tone-Clock supplies the system clock for the cabinet 
displayed:
■ active
: Tone-Clock active and supplying system clock
■ down
: Tone-Clock failed some maintenance activity and cannot 
supply the system clock for this cabinet.
■ <blank> If simplex, then the 1B Tone-Clock for the PPN displays 
blank; if no EPN, then both the 1A and 1B Tone-Clock for this 
EPN display blank.
SYSTEM TONE
Shows which Tone-Clock circuit pack supplies the system tones for 
the cabinet being displayed.
■ active
: Tone-Clock active and supplying system tones
■ down
: Tone-Clock failed some maintenance activity and cannot 
supply the system tones for this cabinet.
■ <blank> If simplex, then the 1B Tone-Clock for the PPN displays 
blank. If the system does not have an EPN, then both the 1A 
and 1B Tone-Clock for this EPN display blank.
TDM
The TDM Bus identifier (
1A
 and 
1B
)
SERVICE STATE
Operational state of the TDM Bus circuit pack:
■ in
: TDM Bus installed and is in-service
■ out
: TDM Bus failed certain maintenance tests and has been 
removed from service
CONTROL 
CHANNEL
IWhether the control channel is on this TDM Bus (
y
 or 
n
)
DEDICATED 
TONES
Whether the dedicated tones are on this TDM Bus (
y
 or 
n
)
PKT
Packet Bus identifier (1). Refer to Packet Bus Maintenance 
descriptions for more information.
SERVICE STATE
The operational state of the Packet Buses:
■ in
: Packet Bus in-service and operating normally.
■ out
: Packet Bus failed certain maintenance tests and has been 
removed from service.
■ <blank> System does not have the Packet Bus feature.
BUS 
ALARMS-MAJOR
Whether Major alarms exist for packet bus components (
y
 or 
n
)
BUS 
ALARMS-MINOR
Whether Minor alarms exist for packet bus components (
y
 or 
n
)