Maintenance Commands 
2-341test hardware-group 
2
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test hardware-group
system
carrier 
location
cabinet 
location
board 
location
print
schedul
e
System-wide test of all 
hardware-groups
Carrier address: cabinet (1), carrier 
(A)
1
Cabinet address (1)
2
Board location: 
PCSS
3
Output sent to printer
Command validated and then a 
scheduling form displays to 
schedule execution of the command. 
The command is then placed in the 
command queue and is executed at 
the specified time. The information 
displayed by the command is sent to 
the system printer instead of the 
screen.
4
Examples:
test hardware-group system
test hardware-group system print
test hardware-group carrier 1a
test hardware-group carrier 1a 
schedule
test hardware-group board 01c07
test hardware-group board 01c07 
schedule
test hardware-group spe
test hardware-group spe print
test hardware-group spe schedule
1 The type of carrier may be port, or processor. In the case of a port carrier, all universal port and tone-clock boards (see 
note 4) and its affiliated MOs residing in the specified carrier are tested. For a processor carrier, all SPE complex and 
tone-clock boards and affiliated MOs are tested.
2 All PN and PNC related MOs plus cabinet specific MOs, including maintenance boards and environment (ring generator, 
battery, power, emergency transfer, external alarms, fans, and temperature) are tested if they reside in the specified 
cabinet location.
3 All MOs on the specified ’board location’ including ports are tested.
4 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
Test 
sequence 
= short; 
repeat = 1
See below