User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Commands 
2-370test processor 
2
Output
The following output example is for the 
test processor a
 command. The 
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
Port
The port address (cabinet-carrier)
Maintenance 
Name
Maintenance object being tested is MEMORY.
Alt. Name
Not applicable.
Test No.
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted. Refer 
to the detailed list of the codes by test number for each MO.
 test processor a SPE B
 TEST RESULTS
 Port Maintenance Name Alt. Name Test No. Result Error Code
 01A PROCR 77 PASS
 01A PROCR 80 PASS
 01A PROCR 82 PASS
 01A PR-MAINT 102 ABORT 1018
 01A PR-MAINT 103 ABORT 1018
 01A PR-MAINT 106 PASS
 01A PR-MAINT 228 PASS
 01A PR-MAINT 229 ABORT 1018
 01A MEMORY 87 PASS
 01A MEMORY 631 PASS
 Command successfully completed