User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-412V-PWR (12 Volt Power Supply) 
3
Table 3-3. 12 Volt Power Supply Test 
Error 
Code Test Result Description/Recommendation
1192 ABORT 12 volt power supply is being used by other applications or by 
maintenance.
1. The 12 volt power supply is in use. Retry the test card-mem 
command after the maintenance operation application is completed.
2106 ABORT Internal system error
2114 1. Retry the command at 1-minute intervals a maximum of 5 times.
109 FAIL The 12 volt power supply unit in the TN798 cannot be turned on by the 
software.
1. Retry the test card-mem command one more time to verify the 
operation of the 12 volt power supply in the TN798.
2. If the failure indicated by Error Code 109 persists, the TN798 must 
be replaced. Follow the standard procedure for replacing the 
TN798.
3. After the new Processor circuit pack is inserted, enter the test 
card-mem command to verify the operations of the 12 volt power 
supply. 
110 FAIL The 12 volt power supply unit in the TN798 cannot be turned off by the 
software.
1. Retry the test card-mem command one more time to verify the 
operation of the 12 volt power supply.
2. If the failure indicated by Error Code 110 persists, the TN798 should 
be scheduled for replacement during the next regular maintenance 
visit. This failure does not cause any service disruption.
PASS The 12 volt power supply unit in the TN798 is functioning correctly.
Continued on next page