User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-9ADX8D-BD (AUDIX Circuit Pack) 
3
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 DEFINITY 
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in 
digital-port (DP) mode. For circuit pack problems, see “XXX-BD (Common Port 
Circuit Pack)”. Port level problems are covered by ADX8D-PT.
DEFINITY AUDIX
 consists of 2 circuit packs that occupy 4 slots in a port cabinet. 
The tests described in this manual apply only to switch-side maintenance which 
tests circuit pack components related to the TDM bus interface. The AUDIX 
system has an extensive maintenance strategy that is described in 
DEFINITY 
AUDIX System Maintenance
, 585-300-110.
MO Name (in 
Alarm Log) Alarm Level Initial Command To Run
1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for example, 
A, B,or C); SS is the address of the slot in the carrier where the circuit pack is located (for 
example, 01, 02, ..., etc.).
Full Name of MO
ADX8D-BD MINOR or 
WARNINGS
test board PCSS sh AUDIX Circuit Pack