Maintenance Objects 
3-26ADX16D-P (16-Port AUDIX Digital Port) 
3
7 FAIL Conference Test failed on the primary channel. In some cases, users may 
not notice a disruption in service. In extreme cases, the conferencing 
feature may not work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may 
range from no noticeable effect to loss of use of this port.
15 FAIL The control channel between the processor and AUDIX is not transmitting 
properly. User impact may range from no noticeable effect to loss of use of 
this port. This failure could also be disruptive to other users.
16 FAIL The secondary voice channel is not transmitting properly. User impact 
may range from no noticeable effect to loss of use of this port.
None FAIL The test failed for reasons external to the AUDIX.
1. Run circuit pack tests to check the tone generator circuit pack and the 
tone detector circuit pack by using the test board PCSS s command.
2. Resolve any problems detected on the tone generator circuit pack or 
tone detector circuit pack.
3. If the tone generator and tone detector circuit packs are functioning 
properly, and if the test still fails, replace the AUDIX (see caution at the 
beginning of this section).
PASS Voice and Control Channel Local Loop test passed. All channels are 
transmitting properly.
1. To be sure that this is not an intermittent problem, repeat this test up to 
10 times and see if it continues to pass.
2. If complaints still exist, examine the connections.
Table 3-10. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error 
Code
Te s t 
Result Description/Recommendation
Continued on next page