User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-36ANL-24-L (24-Port Analog Line) 
3
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time. 
■ 40960 indicates that too many simultaneous incoming ringing 
attempts were made on this board. Only 4 ports on a board may 
ring simultaneously. A 5th incoming call will cause an inline error 
from the board.
■ 40975 indicates that the terminal equipment was on-hook when 
ring-tip was detected during ringing. This usually indicates a failure 
in the terminal equipment or the type of terminal has a low ringer 
Table 3-15. 24-Port Analog Line Error Log Entries 
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1(a) 40960 
40975 
40977
none
15(b) Any Audits and 
Updates Test (#36)
18 0 busy-out station 
extension
WRN ON release station 
<extension>
130(c) None WRN ON test port PCSSpp sh
257(d) 40973 none
513(e) Station Present 
Test (#48)
WRN OFF test port PCSSpp sh r 2
769 Battery Feed Test 
(#35)
MIN/ 
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set 
options command.
ON test port PCSSpp sh r 2
1025 Looparound Test 
(#161)
MIN/ 
WRN
2
ON test port PCSSpp l r 2
1281 Conference Test 
(#7)
MIN/ 
WRN
2
ON test port PCSSpp l r 2
1537 NPE Crosstalk Test 
(#6)
MIN/ 
WRN
2
ON test port PCSSpp l r 2
Continued on next page