User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-73AN-LN-PT (Analog Line Port) 
3
Error log entries and test to clear values
Notes:
a.
Error Type 1
: these are in-line errors and can only be resolved over time. 
■ Aux Data 40960 indicates that too many simultaneous incoming 
ringing attempts were made on this board. Only 4 ports on a board 
may ring simultaneously. A 5th incoming call will cause an inline 
error from the board.
Table 3-29. Analog line error log entries
Error 
Type
Aux 
Data
Associated 
Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1(a) 40960 
40975 
40977
none
15(b) Any Audits and 
Updates Test 
(#36)
18 0 busy station 
extension
WRN ON release station extension
130(c) None WRN ON test port UUCSSpp sh
257(d) 40973 none
513(e) Station 
Present Test 
(#48)
WRN OFF test port UUCSSpp sh r 2
769 Battery Feed 
Test (#35)
MIN/ 
WRN
2
2. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set options command.
ON test port UUCSSpp sh r 2
1025 Looparound 
Test (#161)
MIN/ 
WRN
2
ON test port UUCSSpp l r 2
1281 Conference 
Test (#7)
MIN/ 
WRN
2
ON test port UUCSSpp l r 2
1537 NPE 
Crosstalk Test 
(#6)
MIN/ 
WRN
2
ON test port UUCSSpp l r 2