User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-200ATM PNC-DUP (ATM PNC Duplication) 
3
3. Activate PNC-DUP through the 
change system-parameters duplication
form. This is not allowed if any component of either PNC (A or B) is busied 
out.
4. The system must insert all connectivity-related components for both 
standby and active PNC, a process that takes up to 5 minutes, depending 
upon circuit pack insertion. The process is complete when the first 
terminal login prompt appears.
5. The PNC-DUP initialization anti-thrashing timer must expire (this occurs 5 
minutes after completion of board insertion, PNC interchange, or system 
reset of level 2 or higher).
To disable PNC duplication perform the following sequence of steps:
1. Verify that the A-PNC is active. A forced interchange may be required.
2. Busyout the standby PNC (B-PNC).
3. Turn off the system parameter for PNC-DUP through 
change 
system-parameters duplication
.
4. Remove the B-PNC connectivity by removing the Board Locations on the 
change fiber
 form for ATM-PNC.
5. Remove the B-PNC circuit packs (ATM-EI boards). Use 
change circuit 
pack UUC
.
6. Disable administration of PNC duplication on the 
change 
system-parameters customer-options
 form by changing the 
PNC 
Duplication
 field to 
n
.
NOTE:
Alterations to PNC that involve only the 
addition
 of connectivity can be done 
with PNC-DUP operational. 
Alterations requiring the 
removal
 of connectivity must be done with 
PNC-DUP removed. 
PNC-DUP must be removed and translations should be saved before 
making any hardware changes.
Steady State LEDs
The LEDs of PNC components in a stable duplicated system should appear as 
follows:
■ The 
active
 ATM-EIs in the EPNs are functioning as Archangels. Their 
yellow LED flash pattern is 2 seconds on/200 ms off.
■ The EPN standby EIs yellow LEDs are off.
■ The PPN active EI yellow LED is on steady.
■ The PPN standby EI yellow LED is off.