User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-367CLSFY-PT (Call Classifier Port) 
3
Hardware Error Log Entries and Test to Clear 
Valu es
Notes:
a. There are two possible alarm levels for this error type: major alarm and 
minor alarm. A major alarm is raised if the total number of call classifier 
ports currently in-service is less than or equal to 1/2 of the administered 
threshold number. Otherwise, a minor alarm is raised. In either case, run 
the short test sequence against the port and follow the error code 
procedures for the individual tests.
The threshold number of call classifier ports for service is administered 
using the 
change system-parameters maintenance
 command.
b. The call classifier port lost its translation. Testing the call classifier port is 
sufficient to reload its translation. If testing the call classifier port does not 
clear the error, then the call classifier circuit pack containing the defective 
call classifier port should be replaced.
c. This error indicates the call classifier port is having problems detecting 
system tones (DTMF, etc.) or detecting and generating necessary R2-MFC 
tones. This error should accompany some percentage of failed calls. If this 
error type is persistently logged, then the call classifier circuit pack 
containing the defective call classifier port should be replaced.
Table 3-162. Call Classifier Port (CLSFY-PT) Error Log Entries 
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
1 any Tone Detector 
Audit/Update Test 
(#43)
MAJOR/ 
MINOR (a)
ON test port PCSSpp r 2
18 Port has been 
busied out by 
system technician
WARNING OFF release port PCSSpp
257 (b) 17666 Test (#43) MAJOR/ 
MINOR (a)
ON test port PCSSpp r 3
513 (c) any Tone Detection 
Verification Test 
(#42)
MAJOR/ 
MINOR (a)
ON test port PCSSpp r 3
Continued on next page