User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-395CO-TRK (CO Trunk) 
3
2561 57345 Single polarity ringing current. This error 
results from abnormal ringing current, but 
does not prevent the incoming call from 
being accepted. One cause could be that 
the reverse current detector associated with 
the port is failing. (Will not be detected by 
any tests.) Another cause could be that 
normal current is not detected. In this case, 
neither incoming nor outgoing calls can be 
completed, and the dial tone test also fails. 
The last cause could be that certain types of 
noise are present on the CO line during the 
silent period of ringing.
Check for other errors first and 
then see Note 4 at end of table.
2817 57360 Ground but no ringing. This error occurs on 
an incoming call on a ground-start trunk. If 
ringing is not detected within 5 seconds of 
the Tip being grounded, the call is still 
accepted. If the CO is of the No. 5ESS. 
switch type, ringing delays of more than 5 
seconds during heavy traffic are fairly 
common.
Check for other errors.
2817 57393 On the TN465, the loop is opening too slowly 
after a disconnect. This error indicates an 
on-board problem, although the trunk may 
be functional. On the TN2138, CO released 
the trunk at least 4 minutes after the PBX 
dropped the call. This error code is log-only 
and causes no other testing to occur. No 
alarm is generated.
Check for other errors.
3073 57376 No loop current on incoming call. The 
incoming destination has already answered 
and no loop current has been detected. If 
this is a hard fault, the dial tone test and all 
outgoing calls should also fail.
Check for other errors.
3329 57408 Trunk error. No Tip ground detected on 
outgoing call. This error occurs when an 
attempt is made to seize a ground-start CO 
trunk for an outgoing call and Tip ground is 
not detected or the caller hangs up before 
Tip ground is detected.
See Notes 1 and 2 at end of 
table.
Table 3-172. CO Trunk Errors with NO Tests — Continued
Error 
Type
Aux 
Data Description and System Action System Technician Action
Continued on next page