User's Manual
DEFINITY ECS Release 8.2 Maintenance for R8.2csi 
555-233-119  Issue 1
April 2000
Maintenance Objects 
3-398CO-TRK (CO Trunk) 
3
Table 3-173. TEST #0 Dial Tone Test 
Error 
Code
Te st 
Result Description/ Recommendation
ABORT Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use the command display port PCSSpp to 
determine the trunk group/member number of the port. Use the status 
trunk command to determine the service state of the port. If the service 
state indicates that the port is in use, then the port is unavailable for certain 
tests. You must wait until the port is idle before retesting.
1. If the port status is idle, then retry the command at 1-minute intervals a 
maximum of 5 times.
1001 ABORT System resources required to run this test were not available. This could 
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals a maximum of 5 times.
1004 ABORT The port was seized by a user for a valid call. Use the display port 
PCSSpp command to determine the trunk group/member number of the 
port. Use the status trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. You must wait until the port is idle before 
retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a 
maximum of 5 times.
1005 ABORT Trunk has been administered as incoming-only; dial tone can only be 
obtained on outgoing trunks. This is a normal condition.
1018 ABORT Test has been disabled via administration.
1. Verify that the 
Maintenance Tests? field on the Trunk Group 
Form is set to n. To enable the test, issue the change trunk-group x 
command where "x" equals the number of the trunk group to be tested. 
Then change the entry in the 
Maintenance Tests? field on the 
form to y.
2000 ABORT Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page