Owner's manual
Configuring IP Routing (Layer 3)
7-14 Cajun P550/P220 Switch Operation Guide
To activate an access list:
1.
In the
IP Configuration
section of the Web Agent window, click
Access Control
.
The IP Access Control dialog box opens.
2.
From the
Enable
pull-down menu, select
Enable
to filter inbound traffic.
3.
From the
IP Access List
pull-down menu, select the name of the access list to be
used for filtering when IP access control is enabled.
4.
Click
APPLY
to save your changes,
or
CANCEL
to restore previous settings.
Creating IP Static Routes
To create IP static routes:
1.
In the
IP Configuration
section of the Web Agent window, click
Static Routes
.
The IP Static Routes dialog box opens.
2.
Use Table 7-6 to complete your static route configuration:
3.
Click
CREATE
to save your changes, or
CANCEL
to restore previous settings.
Creating Static ARP Entries
To create a static ARP entry in your switch’s ARP cache:
1.
In the
IP Configuration
section of the Web Agent window, click
Static ARP
. The
IP Static ARP Entries dialog box opens.
2.
Click
CREATE
. The Add IP Static ARP Entry dialog box opens.
Table 7-6. IP Static Route Parameters
Parameter Allows you to...
Network Address Assign an IP network address for your IP static route.
Mask Assign an IP subnet mask for your IP static route.
Next-Hop Address Assign an IP address for the gateway associated with
the IP static route.
Next-Hop Interface Select an interface that is associated with the IP static
route.
Cost Specify the metric between this router and the
destination. Note that this overrides routing protocol
metrics.
Preference Specify a low or high routing preference.