20
DS1 operational and signaling parameters
The table below provides the recommended combination of parameters for each
DS1 interface.
DS1
Circuit
Packs
# Trunk
Members
Bit Rate
Mbps Companding
Signaling
Mode Trunk Type
1
TN722 1-23 1.544 mulaw common-chan Tie,
DMI-BOS,
CO
2
1-24 robbed-bit Tie
TN722B 1-23 1.544 mulaw common-chan Tie,
DMI-BOS,
CO
2
1-24 robbed-bit CO/DID/Tie
TN767D,
E
3
1-23 1.544 mulaw common-chan Tie,
DMI-BOS,
C0
2
1-24 robbed-bit CO/DID/Tie
1-23 (24th
is D-chan)
isdn-pri
4
ISDN
1-24 isdn-ext
4
ISDN
TN464B
5
1-30 2.048 alaw/mulaw
6
CAS CO/DID/Tie
1-31 alaw isdn-pri
4
ISDN
1-31 isdn-ext
4
ISDN
1-23 1.544 mulaw common-chan Tie,
DMI-BOS,
CO
2
Continued on next page